{"product_id":"dts-p302-veterinary-mobile-dental-workstation","title":"DTS-P302 Veterinary Mobile Dental Workstation","description":"\u003cp\u003eThe DTS-P302 is a veterinary mobile dental workstation driven by an electric motor rather than an air turbine. More stable speed, quieter operation, and a low-speed handpiece with four selectable gear ratios — including the reduction ratios that root canal work actually requires.\u003c\/p\u003e\n\n\u003cp\u003ePetMedTools supplies this veterinary dental unit quote-first. Tell us your destination country and expected quantity and we'll issue a formal quotation with a proforma invoice.\u003c\/p\u003e\n\n\u003ch3\u003eElectric motor versus air turbine\u003c\/h3\u003e\n\n\u003cp\u003eMost veterinary dental units drive the low-speed handpiece with compressed air. Air is simple and cheap, and it has one significant weakness: torque collapses under load. Push an air-driven bur into dense bone and the speed drops exactly when you need it not to.\u003c\/p\u003e\n\n\u003cp\u003eAn electric motor holds speed under load. For polishing and sectioning that means consistent cutting rather than stalling and surging, and consistency is what protects both the tooth and the operator's patience.\u003c\/p\u003e\n\n\u003cp\u003eThe manufacturer also cites longer service life and quieter operation, and notes that it reduces fatigue during extended work. Anyone who has done a four-hour dental knows that noise and vibration are cumulative.\u003c\/p\u003e\n\n\u003ch3\u003eFour gear ratios and why two of them exist\u003c\/h3\u003e\n\n\u003cp\u003eThe electric motor offers four speed settings on the low-speed handpiece:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e16:1 — 150-2500 RPM\u003c\/li\u003e\n\u003cli\u003e20:1 — 100-2000 RPM\u003c\/li\u003e\n\u003cli\u003e1:1 — 2000-40000 RPM\u003c\/li\u003e\n\u003cli\u003e1:5 speed increasing — 10000-200000 RPM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe manufacturer states that 16:1 and 20:1 are mainly for root canal treatment. Those are reduction ratios — the handpiece turns slower than the motor, and the trade is torque.\u003c\/p\u003e\n\n\u003cp\u003eEndodontic files break when driven too fast, and a fractured file inside a root canal is a genuinely bad afternoon. Low speed with high torque is the correct configuration, and a unit without reduction ratios simply cannot do endodontics safely. If root canal work is on your roadmap, this specification is the reason to buy this unit rather than a cheaper one.\u003c\/p\u003e\n\n\u003cp\u003eAt the other end, 1:5 speed increasing reaches 200,000 RPM for fine cutting where you want speed rather than force.\u003c\/p\u003e\n\n\u003ch3\u003eWhat's integrated\u003c\/h3\u003e\n\n\u003cp\u003eThe unit combines X-ray shooting, saliva suction, LED curing light, cleaning, grinding, polishing and cutting.\u003c\/p\u003e\n\n\u003cp\u003eComponent detail worth knowing: the low-speed handpiece for polishing runs at 15,000-20,000rpm with inner water spray at 0.15-0.25MPa working pressure. The high-speed handpiece for cutting has an LED light and runs 320,000-400,000rpm. The 3-way syringe delivers water, air and mist. The detachable LED scaler outputs 3W-20W at 0.01Mpa-0.5Mpa water pressure, and the suction handpiece clears saliva and waste water from the mouth.\u003c\/p\u003e\n\n\u003cp\u003eA note on one figure: the low-speed handpiece callout states 15,000-20,000rpm while the specification table lists the low speed hand piece at 20,000-40,000rpm. Both appear in the manufacturer's own catalogue. We've reproduced both rather than picking one, and we'd suggest confirming which applies to your configuration at quotation.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eAir compressor power\/current: 220V:550W\/2.5A, 110V:550W\/5A\u003c\/li\u003e\n\u003cli\u003eAir compressor output pressure: 0.8MPa\u003c\/li\u003e\n\u003cli\u003eAir tank capacity: 10L\u003c\/li\u003e\n\u003cli\u003eUltrasonic scaler power: 3-20W\u003c\/li\u003e\n\u003cli\u003eUltrasonic scaler working pressure: 0.01-0.5MPa\u003c\/li\u003e\n\u003cli\u003eVibration frequency on tips: 28kHz±3kHz\u003c\/li\u003e\n\u003cli\u003eHigh speed hand piece: 320,000-400,000rpm at 0.3-0.35MPa\u003c\/li\u003e\n\u003cli\u003eLow speed hand piece: 20,000-40,000rpm at 0.15-0.20MPa\u003c\/li\u003e\n\u003cli\u003eNoise (air supply process only): 65dB\u003c\/li\u003e\n\u003cli\u003eLED scaler: 3W-20W output, 0.01Mpa-0.5Mpa water pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe 10L tank and 65dB\u003c\/h3\u003e\n\n\u003cp\u003eTank capacity determines how long the compressor stays quiet. A small tank means the motor cycles constantly; 10L gives you a working reservoir so the compressor runs less often.\u003c\/p\u003e\n\n\u003cp\u003e65dB is quoted specifically for the air supply process, and it's roughly conversation level. That matters in a practice where the dental table isn't in a soundproofed room — which is most practices. Noise drives owner perception and staff fatigue in equal measure.\u003c\/p\u003e\n\n\u003ch3\u003eThe mobile part\u003c\/h3\u003e\n\n\u003cp\u003eThis is a mobile workstation on castors with a foot control. Mobility suits practices where dentals happen wherever there's space, or where one unit serves two rooms.\u003c\/p\u003e\n\n\u003cp\u003eTwo practical cautions. Cables and foot pedals are the components that fail on mobile equipment, because they get rolled over and yanked. And a unit that moves needs somewhere to live between cases — decide that before it arrives, or it ends up parked wherever it was last used.\u003c\/p\u003e\n\n\u003ch3\u003eDTS-P302, DTS-280 or DTS-180?\u003c\/h3\u003e\n\n\u003cp\u003eThree units, three different answers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDTS-180\u003c\/strong\u003e is the entry system: oil free air compressor at 550W and 2.4A, 70L\/min airflow, 0.8Mpa exhaust pressure, under 60dB, with an LED-illuminated ultrasonic scaler handpiece and an upgradeable disinfectant system. Scaling, polishing and extraction, no imaging.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDTS-P302\u003c\/strong\u003e adds the electric motor with its four gear ratios and the imaging cart option. This is the endodontics-capable unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDTS-280\u003c\/strong\u003e is the all-in-one: dental unit, X-ray system, oral camera and touch screen displays with two software systems, plus a 180° rotating arm with 80cm*2 arm length and a portable lithium-battery X-ray machine for wireless shooting.\u003c\/p\u003e\n\n\u003cp\u003eOur \u003ca href=\"\/fr\/pages\/veterinary-dental-equipment-buying-guide\"\u003eveterinary dental equipment buying guide\u003c\/a\u003e works through that decision, and the \u003ca href=\"\/fr\/pages\/veterinary-dental-accessories-buying-guide\"\u003eveterinary dental accessories buying guide\u003c\/a\u003e covers what you need alongside whichever you choose.\u003c\/p\u003e\n\n\u003ch3\u003eWater in, water out\u003c\/h3\u003e\n\n\u003cp\u003eThe specification covers what the machine does. It doesn't cover the two plumbing decisions that determine whether installation takes an hour or a week.\u003c\/p\u003e\n\n\u003cp\u003eWater in: the handpieces and scaler need a supply. Self-contained bottle systems give you control over water quality and let you run disinfectant through the lines. Mains-fed systems are less work day to day and less controllable. Bottle systems are generally preferred in veterinary settings for exactly the biofilm reasons that make the disinfectant upgrade worth considering.\u003c\/p\u003e\n\n\u003cp\u003eWater out: suction has to go somewhere, and dental waste carries tissue debris and calculus. Whatever collection or drainage arrangement you choose needs emptying and cleaning on a schedule, and it needs a person assigned to it.\u003c\/p\u003e\n\n\u003cp\u003eNeither of these is difficult. Both are easier decided before delivery than discovered on the day.\u003c\/p\u003e\n\n\u003ch3\u003eBuilding the dental service\u003c\/h3\u003e\n\n\u003cp\u003eEvery dental happens under anaesthesia, and dentals run long. The \u003ca href=\"\/fr\/pages\/veterinary-anesthesia-machine-buying-guide\"\u003eveterinary anesthesia machine buying guide\u003c\/a\u003e and \u003ca href=\"\/fr\/pages\/veterinary-patient-monitor-buying-guide\"\u003eveterinary patient monitor buying guide\u003c\/a\u003e cover matching those to long low-stimulation procedures where hypothermia is the main risk.\u003c\/p\u003e\n\n\u003cp\u003eRadiography is not optional in modern veterinary dentistry — the \u003ca href=\"\/fr\/collections\/dental-x-ray-and-sensor\"\u003edental X-ray and sensor category\u003c\/a\u003e lists options if your unit doesn't include imaging. Instruments and burs sit in \u003ca href=\"\/fr\/collections\/dental-instruments-and-sets\"\u003edental instruments and sets\u003c\/a\u003e, scaler tips in the \u003ca href=\"\/fr\/collections\/dental-ultrasonic-scaler\"\u003edental ultrasonic scaler range\u003c\/a\u003e, consumables in \u003ca href=\"\/fr\/collections\/dental-consumables\"\u003edental consumables\u003c\/a\u003e, and sterilisation in \u003ca href=\"\/fr\/collections\/dental-sterilization\"\u003edental sterilisation\u003c\/a\u003e. The index is at the \u003ca href=\"\/fr\/pages\/buying-guides\"\u003ebuying guides hub\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to confirm before you order\u003c\/h3\u003e\n\n\u003cp\u003eThe DTS-P302 is manufactured by TooToo MediTech Co., Ltd. Everything above comes from the manufacturer's published specification. Four things to settle at quotation:\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVoltage.\u003c\/strong\u003e The compressor is specified for both 220V and 110V. Confirm which you're being quoted.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLow speed handpiece figures.\u003c\/strong\u003e The catalogue prints two different ranges. Get the one that applies to your unit in writing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHandpiece and bur stock.\u003c\/strong\u003e Handpieces are consumable over a few years and burs over a few months. Order spares with the unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eService and warranty.\u003c\/strong\u003e Get warranty length and service arrangements on paper alongside the quotation.\u003c\/p\u003e\n\n\u003ch3\u003eBuying a DTS-P302\u003c\/h3\u003e\n\n\u003cp\u003eWe work quote-first, so there's no price on this page. Send the models you're comparing, expected quantity, destination country and any certification, accessory or packaging requirements. We issue a proforma invoice against that, payment is by USD bank transfer — T\/T, ACH or wire — and we ship once it clears.\u003c\/p\u003e\n\n\u003cp\u003eTell us whether endodontics is part of your plan. That single answer determines which of the three dental units you should be pricing. Comparing across categories? Start from the \u003ca href=\"\/fr\/collections\/all\"\u003efull product range\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"Pet medical equipment","offers":[{"title":"Default Title","offer_id":51673031999803,"sku":"DTS-P302","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/0126\/3419\/files\/3a14f03f30a0944d9eacdf68eab827f2.jpg?v=1789028183","url":"https:\/\/www.petmedtools.com\/fr\/products\/dts-p302-veterinary-mobile-dental-workstation","provider":"Petmedtools","version":"1.0","type":"link"}