{"product_id":"ta-90v-vet-ventilator-anesthesia-machine","title":"TA-90V Vet Ventilator \u0026 Anesthesia Machine","description":"\u003cp\u003eThe TA-90V is a veterinary ventilator and anesthesia machine in one turbine-driven unit. Two-in-one means one trolley, one gas circuit, one set of consumables — and no compressed air supply to plumb, because the turbine drives itself.\u003c\/p\u003e\n\n\u003cp\u003ePetMedTools supplies this veterinary anesthesia ventilator quote-first. Tell us your destination country and expected quantity and we'll issue a formal quotation with a proforma invoice.\u003c\/p\u003e\n\n\u003ch3\u003eTurbine drive and why it changes the install\u003c\/h3\u003e\n\n\u003cp\u003eThe TA-90V is turbine driven. No air source required. If you've ever costed a ventilator install and discovered the compressor and pipework cost as much as the machine, you'll understand why that single line matters.\u003c\/p\u003e\n\n\u003cp\u003eTurbine drive also saves oxygen. On a pneumatically driven ventilator, drive gas is consumed alongside what the patient breathes. Take the drive gas out of that equation and your cylinder lasts longer — which matters most in exactly the practices that can least afford a mid-procedure change.\u003c\/p\u003e\n\n\u003cp\u003eTidal volume runs 5-1500ml. The bottom end is what makes this usable for small animals; 5ml is cat and small-exotic territory, not just a marketing floor.\u003c\/p\u003e\n\n\u003ch3\u003eSix parameters, one screen\u003c\/h3\u003e\n\n\u003cp\u003eThe 10 inch TFT touch screen displays multiple waveforms and 6 parameters simultaneously. Simultaneous is the operative word. An anaesthetist watching a trend across several variables catches deterioration earlier than one cycling through screens.\u003c\/p\u003e\n\n\u003ch3\u003eVentilation modes\u003c\/h3\u003e\n\n\u003cp\u003eVCV, VS, PCV, VPS, SIMV and manual. That set covers volume control, pressure control, support modes and synchronised intermittent mandatory ventilation, plus manual when you want your hand on the bag.\u003c\/p\u003e\n\n\u003cp\u003eWhy does mode range matter in a veterinary setting? Because your patient population spans two orders of magnitude in body weight. A protocol built for a 40kg retriever is wrong for a 3kg cat, and the mode that suits a healthy neuter is wrong for a compromised thoracotomy. Having pressure and volume modes on the same machine means you're not choosing your ventilation strategy based on what the equipment can do.\u003c\/p\u003e\n\n\u003ch3\u003eIntegrated design\u003c\/h3\u003e\n\n\u003cp\u003eVentilator and anesthesia machine share one chassis, with built-in bellows and breathing circuit. Fewer connections, fewer leak points, fewer things to assemble at seven in the morning.\u003c\/p\u003e\n\n\u003cp\u003eTwo AC power outputs are built in, so the machine powers collaborating devices — your monitor, your warming unit — without adding another extension lead to the floor around the table.\u003c\/p\u003e\n\n\u003ch3\u003eThree installation options\u003c\/h3\u003e\n\n\u003cp\u003eDesktop, wall-mounted or trolley mounted. Wall mounting frees floor space in a cramped theatre. Trolley mounting suits a practice that moves equipment between rooms. Desktop works when the machine lives permanently beside one table.\u003c\/p\u003e\n\n\u003cp\u003eDecide before you order. Retrofitting a wall mount after delivery usually means calling someone in.\u003c\/p\u003e\n\n\u003ch3\u003eBattery and gas monitoring\u003c\/h3\u003e\n\n\u003cp\u003ePower support runs a minimum of 2 hours on a fully charged battery under standard operation. That's not designed as a portable-use feature — it's a mains-failure margin. Two hours is enough to finish a procedure and recover a patient properly rather than making decisions under pressure.\u003c\/p\u003e\n\n\u003cp\u003eGas monitoring is optional configuration for CO2 and anesthesia gas. Specify it at quotation if you want it; retrofitting monitoring is rarely as simple as it sounds.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eTidal volume: 5-1500ml\u003c\/li\u003e\n\u003cli\u003eTouch screen: 10 inch TFT\u003c\/li\u003e\n\u003cli\u003eSimultaneous display: multiple waveforms and 6 parameters\u003c\/li\u003e\n\u003cli\u003eVentilation modes: VCV, VS, PCV, VPS, SIMV and manual\u003c\/li\u003e\n\u003cli\u003eDrive: turbine, no air source required\u003c\/li\u003e\n\u003cli\u003ePower support: min 2hrs on fully charged battery under standard operation\u003c\/li\u003e\n\u003cli\u003ePower outputs: two AC\u003c\/li\u003e\n\u003cli\u003eInstallation: desktop, wall-mounted or trolley mounted\u003c\/li\u003e\n\u003cli\u003eDesign: 2-in-1 ventilator and anesthesia machine, built-in bellows and breathing circuit\u003c\/li\u003e\n\u003cli\u003eGas monitoring: optional configuration for CO2 and anesthesia gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTidal volume and what 5ml actually means\u003c\/h3\u003e\n\n\u003cp\u003eA 5-1500ml range spans a 300-fold difference. That range is the reason a general practice can run one machine instead of two.\u003c\/p\u003e\n\n\u003cp\u003eAt the bottom end you're ventilating cats, rabbits, ferrets and small exotics, where accuracy matters far more than capacity — deliver 15ml when you meant 10 and you've overventilated a small patient significantly. At the top you're covering large breed dogs through long procedures. Most veterinary ventilators handle one end well and the other adequately, so it's worth asking us how the machine performs at the specific weights you see most.\u003c\/p\u003e\n\n\u003cp\u003eBring your case mix to the quotation conversation. A practice doing mostly cat neuters and a practice doing mostly large-breed orthopaedics should be asking different questions about the same machine.\u003c\/p\u003e\n\n\u003ch3\u003eCircuits are a per-patient decision\u003c\/h3\u003e\n\n\u003cp\u003eThe machine ships with a built-in breathing circuit, but circuit selection still varies by patient weight in daily practice. Rebreathing circuits suit larger patients and conserve gas and heat; non-rebreathing circuits reduce resistance for small ones.\u003c\/p\u003e\n\n\u003cp\u003eWhatever you choose, circuits and bags are consumables. Budget for the recurring cost, not just the machine — and confirm at quotation which circuit type and sizes ship with the unit, because \"built-in breathing circuit\" on a specification sheet doesn't tell you how many spares arrive in the crate.\u003c\/p\u003e\n\n\u003ch3\u003eTA-90V or TA80V?\u003c\/h3\u003e\n\n\u003cp\u003eThe TA80V is the sibling model, also a 2-in-1 turbine-driven ventilator and anesthesia machine. It carries a 9 inch HD touch screen against the TA-90V's 10 inch TFT, and adds a few features the TA-90V listing doesn't mention: mixing O2 and air for the patient, a circuit heating function that warms gas and evaporates internal moisture, an independent one-step ACGO switch, and a 1000ml CO2 absorber canister sized to reduce dead space.\u003c\/p\u003e\n\n\u003cp\u003eThe published specifications overlap heavily and describe different feature sets rather than a clear tier. Ask us to confirm the exact difference against your case mix at quotation stage — we'd rather get it in writing from the manufacturer than guess on your behalf.\u003c\/p\u003e\n\n\u003ch3\u003eBuilding the anaesthesia workflow\u003c\/h3\u003e\n\n\u003cp\u003eA ventilator is one component. Monitoring has to match it, and the \u003ca href=\"\/ru\/pages\/veterinary-patient-monitor-buying-guide\"\u003eveterinary patient monitor buying guide\u003c\/a\u003e covers parameter selection for surgical caseloads. Broader context sits in the \u003ca href=\"\/ru\/pages\/veterinary-anesthesia-equipment-buying-guide\"\u003eveterinary anesthesia equipment buying guide\u003c\/a\u003e and the \u003ca href=\"\/ru\/pages\/veterinary-anesthesia-machine-buying-guide\"\u003eveterinary anesthesia machine buying guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eInduction chambers matter for fractious patients and exotics — see the \u003ca href=\"\/ru\/pages\/veterinary-induction-chamber-buying-guide\"\u003eveterinary induction chamber buying guide\u003c\/a\u003e. Oxygen supply planning is covered in the \u003ca href=\"\/ru\/pages\/veterinary-oxygen-equipment-buying-guide\"\u003eveterinary oxygen equipment buying guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eCircuits, bags and masks are recurring costs rather than one-off ones. The \u003ca href=\"\/ru\/collections\/anaesthesia-consumables\"\u003eanaesthesia consumables range\u003c\/a\u003e and \u003ca href=\"\/ru\/collections\/anaesthesia-masks\"\u003eanaesthesia masks\u003c\/a\u003e list what fits, and the full index is at the \u003ca href=\"\/ru\/pages\/buying-guides\"\u003ebuying guides hub\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to confirm before you order\u003c\/h3\u003e\n\n\u003cp\u003eThe TA-90V is manufactured by TooToo MediTech Co., Ltd. Everything above comes from the manufacturer's published specification. Four things to settle at quotation:\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVaporiser.\u003c\/strong\u003e Which agent, which fitting, and is it included. This is the most common gap between an anaesthesia machine quotation and a working theatre.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation type.\u003c\/strong\u003e Desktop, wall or trolley — decide before shipping.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGas monitoring.\u003c\/strong\u003e Optional means it has to be specified, not assumed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eService and warranty.\u003c\/strong\u003e Get warranty length and service arrangements in writing with the quotation.\u003c\/p\u003e\n\n\u003ch3\u003eBuying a TA-90V\u003c\/h3\u003e\n\n\u003cp\u003eWe work quote-first, so there's no price on this page. Send the models you're comparing, expected quantity, destination country and any certification, accessory or packaging requirements. We issue a proforma invoice against that, payment is by USD bank transfer — T\/T, ACH or wire — and we ship once it clears.\u003c\/p\u003e\n\n\u003cp\u003eBulk pricing, distributor terms, OEM questions and region limits are settled at quotation. Comparing across categories? Start from the \u003ca href=\"\/ru\/collections\/all\"\u003efull product range\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003eSend your typical patient weight range and preferred installation type with the enquiry and the quotation comes back specific rather than generic.\u003c\/p\u003e\n","brand":"Pet medical equipment","offers":[{"title":"Default Title","offer_id":51673032130875,"sku":"TA90V","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/0126\/3419\/files\/7c350363490798f37d249b1709004dad.jpg?v=1789028199","url":"https:\/\/www.petmedtools.com\/ru\/products\/ta-90v-vet-ventilator-anesthesia-machine","provider":"Petmedtools","version":"1.0","type":"link"}