Перейти к информации о продукте
1 из 1

Pet medical equipment

TA-90V Vet Ventilator & Anesthesia Machine

TA-90V Vet Ventilator & Anesthesia Machine

Price on request
Сумма налога включена. Стоимость доставки рассчитывается при оформлении заказа.

Request a Quote

Tell us the quantity and destination — we reply with a proforma invoice and payment details. We accept USD bank transfer (T/T), ACH and wire.

Chat on WhatsApp — instant reply

The TA-90V is a veterinary ventilator and anesthesia machine in one turbine-driven unit. Two-in-one means one trolley, one gas circuit, one set of consumables — and no compressed air supply to plumb, because the turbine drives itself.

PetMedTools supplies this veterinary anesthesia ventilator quote-first. Tell us your destination country and expected quantity and we'll issue a formal quotation with a proforma invoice.

Turbine drive and why it changes the install

The TA-90V is turbine driven. No air source required. If you've ever costed a ventilator install and discovered the compressor and pipework cost as much as the machine, you'll understand why that single line matters.

Turbine drive also saves oxygen. On a pneumatically driven ventilator, drive gas is consumed alongside what the patient breathes. Take the drive gas out of that equation and your cylinder lasts longer — which matters most in exactly the practices that can least afford a mid-procedure change.

Tidal volume runs 5-1500ml. The bottom end is what makes this usable for small animals; 5ml is cat and small-exotic territory, not just a marketing floor.

Six parameters, one screen

The 10 inch TFT touch screen displays multiple waveforms and 6 parameters simultaneously. Simultaneous is the operative word. An anaesthetist watching a trend across several variables catches deterioration earlier than one cycling through screens.

Ventilation modes

VCV, VS, PCV, VPS, SIMV and manual. That set covers volume control, pressure control, support modes and synchronised intermittent mandatory ventilation, plus manual when you want your hand on the bag.

Why does mode range matter in a veterinary setting? Because your patient population spans two orders of magnitude in body weight. A protocol built for a 40kg retriever is wrong for a 3kg cat, and the mode that suits a healthy neuter is wrong for a compromised thoracotomy. Having pressure and volume modes on the same machine means you're not choosing your ventilation strategy based on what the equipment can do.

Integrated design

Ventilator and anesthesia machine share one chassis, with built-in bellows and breathing circuit. Fewer connections, fewer leak points, fewer things to assemble at seven in the morning.

Two AC power outputs are built in, so the machine powers collaborating devices — your monitor, your warming unit — without adding another extension lead to the floor around the table.

Three installation options

Desktop, wall-mounted or trolley mounted. Wall mounting frees floor space in a cramped theatre. Trolley mounting suits a practice that moves equipment between rooms. Desktop works when the machine lives permanently beside one table.

Decide before you order. Retrofitting a wall mount after delivery usually means calling someone in.

Battery and gas monitoring

Power support runs a minimum of 2 hours on a fully charged battery under standard operation. That's not designed as a portable-use feature — it's a mains-failure margin. Two hours is enough to finish a procedure and recover a patient properly rather than making decisions under pressure.

Gas monitoring is optional configuration for CO2 and anesthesia gas. Specify it at quotation if you want it; retrofitting monitoring is rarely as simple as it sounds.

Specifications

  • Tidal volume: 5-1500ml
  • Touch screen: 10 inch TFT
  • Simultaneous display: multiple waveforms and 6 parameters
  • Ventilation modes: VCV, VS, PCV, VPS, SIMV and manual
  • Drive: turbine, no air source required
  • Power support: min 2hrs on fully charged battery under standard operation
  • Power outputs: two AC
  • Installation: desktop, wall-mounted or trolley mounted
  • Design: 2-in-1 ventilator and anesthesia machine, built-in bellows and breathing circuit
  • Gas monitoring: optional configuration for CO2 and anesthesia gas

Tidal volume and what 5ml actually means

A 5-1500ml range spans a 300-fold difference. That range is the reason a general practice can run one machine instead of two.

At the bottom end you're ventilating cats, rabbits, ferrets and small exotics, where accuracy matters far more than capacity — deliver 15ml when you meant 10 and you've overventilated a small patient significantly. At the top you're covering large breed dogs through long procedures. Most veterinary ventilators handle one end well and the other adequately, so it's worth asking us how the machine performs at the specific weights you see most.

Bring your case mix to the quotation conversation. A practice doing mostly cat neuters and a practice doing mostly large-breed orthopaedics should be asking different questions about the same machine.

Circuits are a per-patient decision

The machine ships with a built-in breathing circuit, but circuit selection still varies by patient weight in daily practice. Rebreathing circuits suit larger patients and conserve gas and heat; non-rebreathing circuits reduce resistance for small ones.

Whatever you choose, circuits and bags are consumables. Budget for the recurring cost, not just the machine — and confirm at quotation which circuit type and sizes ship with the unit, because "built-in breathing circuit" on a specification sheet doesn't tell you how many spares arrive in the crate.

TA-90V or TA80V?

The TA80V is the sibling model, also a 2-in-1 turbine-driven ventilator and anesthesia machine. It carries a 9 inch HD touch screen against the TA-90V's 10 inch TFT, and adds a few features the TA-90V listing doesn't mention: mixing O2 and air for the patient, a circuit heating function that warms gas and evaporates internal moisture, an independent one-step ACGO switch, and a 1000ml CO2 absorber canister sized to reduce dead space.

The published specifications overlap heavily and describe different feature sets rather than a clear tier. Ask us to confirm the exact difference against your case mix at quotation stage — we'd rather get it in writing from the manufacturer than guess on your behalf.

Building the anaesthesia workflow

A ventilator is one component. Monitoring has to match it, and the veterinary patient monitor buying guide covers parameter selection for surgical caseloads. Broader context sits in the veterinary anesthesia equipment buying guide and the veterinary anesthesia machine buying guide.

Induction chambers matter for fractious patients and exotics — see the veterinary induction chamber buying guide. Oxygen supply planning is covered in the veterinary oxygen equipment buying guide.

Circuits, bags and masks are recurring costs rather than one-off ones. The anaesthesia consumables range and anaesthesia masks list what fits, and the full index is at the buying guides hub.

What to confirm before you order

The TA-90V is manufactured by TooToo MediTech Co., Ltd. Everything above comes from the manufacturer's published specification. Four things to settle at quotation:

Vaporiser. Which agent, which fitting, and is it included. This is the most common gap between an anaesthesia machine quotation and a working theatre.

Installation type. Desktop, wall or trolley — decide before shipping.

Gas monitoring. Optional means it has to be specified, not assumed.

Service and warranty. Get warranty length and service arrangements in writing with the quotation.

Buying a TA-90V

We work quote-first, so there's no price on this page. Send the models you're comparing, expected quantity, destination country and any certification, accessory or packaging requirements. We issue a proforma invoice against that, payment is by USD bank transfer — T/T, ACH or wire — and we ship once it clears.

Bulk pricing, distributor terms, OEM questions and region limits are settled at quotation. Comparing across categories? Start from the full product range.

Send your typical patient weight range and preferred installation type with the enquiry and the quotation comes back specific rather than generic.

Просмотреть всю информацию