M6/M6E/M6S Series Mini Veterinary Monitor

M6/M6E/M6S Series Mini Veterinary Monitor

Regular price $300.00
Regular price Sale price $300.00
Sale Sold out
Tax included.
Model

The smallest compact vital signs monitor footprint in the world.
Accurate Perfusion Index Pl.=0.05%.With revolutionary, advanced movement compensation.
Provide the parameter of Pl(Perfusion Index0.05%-20%)
Accurate measurement in all kinds of extreme environment measurement.Such as small animal
and shock patients.
NIBP adopts two patents in NIBP, SAWAA(Self-Adaptive-Waveform-Amplitude-adjustment), and SAFD(Self-Adaptive-fast-Deflation)algorithms.similar to Petmap method.

M-Series monitors configuration
M6 = ECG SpO2+NIBP TEMP
M6E = SpO2+NIBP TEMP MainStream EtCO2
M6SE = SpO2+NIBP+TEMP+SideStream EtCO2
Two measurement modes:Spot or Monitoring modes
Data storage capabilities-historical data view, trendgraph view.
Monitoring mode-continuous recording,48 hours of measurement data.
Spot mode-100 user ID's,each user can store 200 data sets.
Audible and visual alarms, with upper and lower alarm limit adjustment
Lithium Battery or AAA battery.
Optional Silicon case and Charging stand.

M6 Series Mini Veterinary Monitor

NIBP:

M6 Series Mini Veterinary Monitor

Oxygen Saturation(%Spo2):

Measurement range
Sp02:0-100% PR:0-350bpm
Perfusion index:0.05%-20%
Accuracy range:
SpO2 saturation:70-100%
Pulse rate:20-500BPM
Perfusion Index:0.025%-20%
Measurement accuracy
SpO2:Big animal +2%(70-100%)Small animal:±3%(70-100%),Not defined in<70%
On motion condition +3% PR:Big/Small animal±3%, on motion condition:+3%
Perfusion Index:0.05%-20%
Resolution
SpO2 saturation:1%
Pulse rate:1BPM

Temperature
Measurement range:25-45C
Resolution:0.1℃
Accuracy:±0.1%

Others
Operation time:8 hours for normal operation
Temperature:Operating:0℃~45℃
Transportation:-20℃~65℃
Humidity:Operating:15%to 90%noncondensing
Storage:0%to 95%noncondensing
Altitude:Operating Altitude:Up to 5000 meters

ECG:
Lead type
3-leads or 5-leads.
Waveform selection: 3-leads:l,Il,ll
5-leads:I,Il,IIl,AVR,AVL,AVF,V
Gain Setting:x0.25,x0.5,x1,x2
Filter Setting:Diagnosis (diagnosis mode),Monitor (monitoring mode),
Surgery (surgery mode),Gain Gain wave mode).
Notch Filter: 50Hz,60Hz,off.
Wave velocity:6.25mm/s,12.5mm/s, 25mm/s.
Storage time: 4s,6s,8s,10s,12s,14s, 16s,30s,60s,120s.
Calibration signal: on,off.  Bandwidth:
Diagnosis mode 0.05~130Hz
Monitoring mode 0.5~40Hz
Operation mode 1~20Hz
Electrode polarization voltage range: 300mV
Pacing pulse detection:
Amplitude:±2mV~±700mV
Vidth:0.1ms~2ms ☐Rise time:10us~100μs
Baseline recovery time:<3 seconds after defibrillation
Signal range:8mV(peak-to-peak value)
Calibration signal:1mV (peak-to-peak value),accuracy 5%.